 Cement soft scouring instrument

Cement mortar fluidity tester

Release time: October 24, 2016 popularity: three hundred and ninety-five

Nld-3 type Cement mortar fluidity tester (cement electric skip table) is mainly used for fluidity test of cement mortar. The products meet the requirements of GB / t2419-2004. It is mainly used to determine the flow value of mortar of pozzolanic Portland cement and masonry cement, so as to determine the water consumption of standard consistency of cement mortar. It is only used for testing equipment in Colleges and universities, building materials, construction engineering, road traffic and laboratory.  

The main technical parameters of cement mortar fluidity tester are as follows:

Total vibration part: 4.35kg ± 0.15kg
Vibration part drop: 10 mm ± 0.2 mm
Vibration frequency: 1Hz
Vibration frequency: 25 times self stop
Net weight: ≈ 20 kg

Installation and commissioning of cement mortar fluidity tester:

It must be fixed on the base with expansion bolt. The instrument base is made of concrete (or brick concrete foundation), with the bottom size of 400mm × 400mm and height of 690mm. The gasket should be filled between the base and the instrument frame (see Fig. 8. Foundation installation drawing). The table top level can be adjusted by adjusting the height of the washer. After the instrument is installed, the table top of the instrument should be horizontal when measured along two diameter directions at right angles to each other. If the standard value of the flow table (jb01) is set, the difference between the measured value and the standard value of the flow table (W1) should be used.

Use method of cement mortar fluidity tester:

The preparation and filling method of the sample shall be in accordance with the relevant provisions of gb2419-2005 and GB 17671-1999, and the appendix of this specification can also be referred to.

1. Before use, please check the drop distance with the inspection gauge.

2. Connect the plug into the corresponding hole after the counter, and turn on the power supply of the counter.

3. If the jump table is not used within 24 hours, skip 25 times in a cycle.

Maintenance of cement mortar fluidity tester:

After use, clean the instrument, remove the residual mortar around the instrument, and lightly lubricate the push rod, table top and cam surface with light oil. If it is not used for a long time, the instrument should be protected from dust and the controller should be placed in the packing box.

If the instrument does not count, please check whether the proximity switch is loose and whether the clearance between the proximity switch and the cam is 1 mm ~ 2 mm. If there is deviation or looseness, please adjust the clearance and tighten it.